 Product Specification
RoHS-6 Compliant 10Gb/s 10km Single Mode Datacom SFP+ Transceiver FTLX1471D3BCL
PRODUCT FEATURES * * * * * * * * * * * Hot-pluggable SFP+ footprint Supports 9.95 to 10.3Gb/s bit rates Power dissipation < 1W RoHS-6 compliant (lead-free) Commercial temperature range -5C to 70C Single 3.3V power supply Maximum link length of 10km Uncooled 1310nm DFB laser Receiver limiting electrical interface Duplex LC connector Built-in digital diagnostic functions * 10GBASE-LR/LW 10G Ethernet
APPLICATIONS
Finisar's FTLX1471D3BCL 10Gb/s Enhanced Small Form Factor Pluggable SFP+ transceivers are designed for use in 10-Gigabit Ethernet links up to 10km over Single Mode fiber. They are compliant with SFF-84311, SFF-84322 and IEEE 802.3ae 10GBASE-LR/LW3. Digital diagnostics functions are available via a 2-wire serial interface, as specified in SFF-84724. The FTLX1471D3BCL is a "limiting module", i.e., it employs a limiting receiver. Host board designers using an EDC PHY IC should follow the IC manufacturer's recommended settings for interoperating the host-board EDC PHY with a limiting receiver SFP+ module. The transceiver is RoHS compliant and lead free per Directive 2002/95/EC5, and Finisar Application Note AN-20386.
PRODUCT SELECTION
FTLX1471D3BCL
(c) Finisar Corporation - May 2008 Rev. B Page 1
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
I.
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Pin Descriptions
Symbol VEET TFAULT TDIS SDA SCL MOD_ABS RS0 RX_LOS RS1 VEER VEER RDRD+ VEER VCCR VCCT VEET TD+ TDVEET Name/Description Transmitter Ground Transmitter Fault Transmitter Disable. Laser output disabled on high or open. 2-wire Serial Interface Data Line 2-wire Serial Interface Clock Line Module Absent. Grounded within the module Rate Select 0. Not Used. Loss of Signal indication. Logic 0 indicates normal operation. Rate Select 1. Not Used. Receiver Ground Receiver Ground Receiver Inverted DATA out. AC Coupled. Receiver Non-inverted DATA out. AC Coupled. Receiver Ground Receiver Power Supply Transmitter Power Supply Transmitter Ground Transmitter Non-Inverted DATA in. AC Coupled. Transmitter Inverted DATA in. AC Coupled. Transmitter Ground Ref. 1 2 3 2 2 2 4 5 4 1 1
1
1
1
Notes: 1. Circuit ground is internally isolated from chassis ground. 2. T is an open collector/drain output, which should be pulled up with a 4.7k - 10k Ohms resistor on
FAULT
3. 4. 5.
the host board if intended for use. Pull up voltage should be between 2.0V to Vcc + 0.3V. A high output indicates a transmitter fault caused by either the TX bias current or the TX output power exceeding the preset alarm thresholds. A low output indicates normal operation. In the low state, the output is pulled to <0.8V. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V. Internally pulled down per SFF-8431 Rev 2.0. LOS is open collector output. Should be pulled up with 4.7k - 10k on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
VeeT 1 VeeT TD2 TX_Fault TD+ 3 TX_Disable VeeT 4 SDA VccT
20
19
18
17
16
Towards Bezel
5
SCL VccR 15
6
MOD_ABS VeeR 14
Towards ASIC
7
RS0 RD+ 13
8
RX_LOS RD12
9
RS1 VeeR 11 VeeR
10
Figure 1. Diagram of Host Board Connector Block Pin Numbers and Names.
(c) Finisar Corporation - May 2008
Rev.B
Page 2
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
II. Absolute Maximum Ratings Exceeding the limits below may damage the transceiver module permanently.
Parameter Maximum Supply Voltage Storage Temperature Relative Humidity 1. Non-condensing. Symbol Vcc TS RH Min -0.5 -40 0 Typ Max 4.0 85 85 Unit V C % Ref.
1
III.
Electrical Characteristics (TOP = -5 to 70 C, VCC = 3.14 to 3.46 Volts)
Parameter Symbol Min Typ Max Unit Ref. Supply Voltage Vcc 3.14 3.30 3.46 V Supply Current Icc 200 285 mA Transmitter Input differential impedance Rin 100 1 Differential data input swing Vin,pp 180 700 mV Transmit Disable Voltage VD 2 Vcc V Transmit Enable Voltage VEN Vee Vee+ 0.8 V Receiver Differential data output swing Vout,pp 300 850 mV 2,6 Output rise time and fall time Tr, Tf 28 ps 3 LOS Fault VLOS fault 2 VccHOST V 4 LOS Normal VLOS norm Vee Vee+0.8 V 4 Power Supply Noise Tolerance VccT/VccR Per SFF-8431 Rev 2.1 mVpp 5 Notes: 1. Connected directly to TX data input pins. AC coupling from pins into laser driver IC. 2. Into 100 differential termination. 3. 20 - 80%. Measured with Module Compliance Test Board and OMA test pattern. Use of four 1's and four 0's sequence in the PRBS 9 is an acceptable alternative. SFF-8431 Rev 2.1. 4. LOS is an open collector output. Should be pulled up with 4.7k - 10k on the host board. Normal operation is logic 0; loss of signal is logic 1. 5. See Section 2.8.3 of SFF-8431 Rev 2.1. 6. The FTLX1471D3BCL is a "limiting module", i.e., it employs a limiting receiver. Host board designers using an EDC PHY IC should follow the IC manufacturer's recommended settings for interoperating the host-board EDC PHY with a limiting receiver SFP+ module.
IV.
Optical Characteristics (TOP = -5 to 70 C, VCC3 = 3.14 to 3.46 Volts)
Symbol POMA PAVE SMSR ER TDP POFF Txj Min -5.2 -8.2 1260 30 3.5 +0.5 1355 Typ Max Unit dBm dBm nm dB dB dB dBm 1 Ref.
Parameter Transmitter Optical Modulation Amplitude (OMA) Average Launch Power Optical Wavelength Side-Mode Suppression Ratio Optical Extinction Ratio Transmitter and Dispersion Penalty Average Launch power of OFF transmitter Tx Jitter
3.2 -30 Per 802.3ae requirements
(c) Finisar Corporation - May 2008
Rev.B
Page 3
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
Relative Intensity Noise Receiver Receiver Sensitivity (OMA) @ 10.3Gb/s Stressed Receiver Sensitivity (OMA) @ 10.3Gb/s Average Receive Power Optical Center Wavelength Receiver Reflectance LOS De-Assert LOS Assert LOS Hysteresis
RIN RSENS1 RSENS2 PAVE C Rrx LOSD LOSA -14.2 1260
-128 -12.6 -10.3 +0.5 1600 -12 -17
dB/Hz dBm dBm dBm nm dB dBm dBm dB 2 3
-30 0.5
Notes: 1. Average power figures are informative only, per IEEE 802.3ae. 2. Valid between 1260 and 1355 nm. Measured with worst ER; BER<10-12; 231 - 1 PRBS. 3. Valid between 1260 and 1355 nm. Per IEEE 802.3ae.
V.
General Specifications
Symbol BR BER LMAX Min 9.95 Typ Max 10.3 10-12 Units Gb/s km Ref. 1 2 1
Parameter Bit Rate Bit Error Ratio Max. Supported Link Length Notes: 1. 10GBASE-LR, 10GBASE-LW. 2. Tested with a 231 - 1 PRBS.
10
VI. Environmental Specifications Finisar FTLX1471D3BCL transceivers have an operating temperature range from -5C to +70C case temperature.
Parameter Case Operating Temperature Storage Temperature Symbol Top Tsto Min -5 -40 Typ Max 70 85 Units C C Ref.
VII. Regulatory Compliance Finisar transceivers are Class 1 Laser Products and comply with US FDA regulations. These products are certified by TUV and CSA to meet the Class 1 eye safety requirements of EN (IEC) 60825 and the electrical safety requirements of EN (IEC) 60950. Copies of certificates are available at Finisar Corporation upon request.
(c) Finisar Corporation - May 2008
Rev.B
Page 4
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
VIII. Digital Diagnostic Functions Finisar FTLX1471D3BCL SFP+ transceivers support the 2-wire serial communication protocol as defined in the SFP MSA1. It is very closely related to the E2PROM defined in the GBIC standard, with the same electrical specifications. The standard SFP serial ID provides access to identification information that describes the transceiver's capabilities, standard interfaces, manufacturer, and other information. Additionally, Finisar SFP+ transceivers provide a enhanced digital diagnostic monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage. It also defines a sophisticated system of alarm and warning flags, which alerts end-users when particular operating parameters are outside of a factory set normal range. The SFP MSA defines a 256-byte memory map in E2PROM that is accessible over a 2-wire serial interface at the 8 bit address 1010000X (A0h). The digital diagnostic monitoring interface makes use of the 8 bit address 1010001X (A2h), so the originally defined serial ID memory map remains unchanged. The interface is identical to, and is thus fully backward compatible with both the GBIC Specification and the SFP Multi Source Agreement. The complete interface is described in Finisar Application Note AN2030: "Digital Diagnostics Monitoring Interface for SFP Optical Transceivers". The operating and diagnostics information is monitored and reported by a Digital Diagnostics Transceiver Controller (DDTC) inside the transceiver, which is accessed through a 2-wire serial interface. When the serial protocol is activated, the serial clock signal (SCL, Mod Def 1) is generated by the host. The positive edge clocks data into the SFP transceiver into those segments of the E2PROM that are not write-protected. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA, Mod Def 2) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. For more information, please see the SFP MSA documentation1,5 and Finisar Application Note AN-2030. Please note that evaluation board FDB-1018 is available with Finisar ModDEMO software that allows simple to use communication over the 2-wire serial interface.
(c) Finisar Corporation - May 2008
Rev.B
Page 5
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
IX. Digital Diagnostic Specifications FTLX1471D3BCL transceivers can be used in host systems that require either internally or externally calibrated digital diagnostics.
Parameter Symbol Accuracy Internally measured transceiver DDTemperature temperature Internally measured transceiver DDVoltage supply voltage Measured TX bias current DDBias Measured TX output power DDTx-Power Measured RX received average DDRx-Power optical power Dynamic Range for Rated Accuracy Internally measured transceiver DDTemperature temperature Internally measured transceiver DDVoltage supply voltage Measured TX bias current DDBias Measured TX output power DDTx-Power Measured RX received average DDRx-Power optical power Max Reporting Range Internally measured transceiver DDTemperature temperature Internally measured transceiver DDVoltage supply voltage Measured TX bias current DDBias Measured TX output power DDTx-Power Measured RX received average DDRx-Power optical power Min Typ Max 3 3 10 2 2 Units C % % dB dB 1 Ref.
-5 3.1 0 -8.2 -14.2
70 3.5 tbd +0.5 +0.5
C V mA dBm dBm
-40 2.8 0 -10 -22
125 4.0 20 +2 +2
C V mA dBm dBm
Notes: 1. Accuracy of measured Tx bias current is 10% of the actual bias current from the laser driver to the laser.
(c) Finisar Corporation - May 2008
Rev.B
Page 6
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
X.
Mechanical Specifications
Finisar FTLX8571D3BCL SFP+ transceivers are compatible with the SFF-8432 specification for improved pluggable form factor, and shown here for reference purposes only. Bail color is blue.
Figure 2. FTLX1471D3BCL Mechanical Dimensions.
(c) Finisar Corporation - May 2008
Rev.B
Page 7
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
XI. PCB Layout and Bezel Recommendations
(c) Finisar Corporation - May 2008
Rev.B
Page 8
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
(c) Finisar Corporation - May 2008
Rev.B
Page 9
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
XII.
Host - Transceiver Interface Block Diagram
Figure 6-Host-Module Interface
(c) Finisar Corporation - May 2008
Rev.B
Page 10
FTLX1471D3BCL Datacom SFP+ Product Specification - May 2008
XIII. References 1. "Specifications for Enhanced 8.5 and 10 Gigabit Small Form Factor Pluggable Module `SFP+ `", SFF Document Number SFF-8431, Revision 21. 2. "Improved Pluggable Form factor", SFF Document Number SFF-8432, Revision 4.2, April 18, 2007.
3. IEEE Std 802.3ae, Clause 52, PMD Type 10GBASE-LR. IEEE Standards Department. 4. "Digital Diagnostics Monitoring Interface for Optical Transceivers". SFF Document Number SFF-8472, Revision 10.1, March 1, 2007. 5. Directive 2002/95/EC of the European Council Parliament and of the Council, "on the restriction of the use of certain hazardous substances in electrical and electronic equipment". January 27, 2003. 6. "Application Note AN-2038: Finisar Implementation Of RoHS Compliant Transceivers", Finisar Corporation, January 21, 2005.
XIV. For More Information Finisar Corporation 1389 Moffett Park Drive Sunnyvale, CA 94089-1133 Tel. 1-408-548-1000 Fax 1-408-541-6138 sales@finisar.com www.finisar.com
(c) Finisar Corporation - May 2008
Rev.B
Page 11


▲Up To Search▲   

 
Price & Availability of FTLX1471D3BCL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X